SKRIPSI Jurusan Teknik Sipil - Fakultas Teknik UM, 2010

Ukuran Huruf:  Kecil  Sedang  Besar

STUDI PERBANDINGAN METODE PERHITUNGAN PADA PELAT KONVENSIONAL DAN PELAT JOIST TUNGGAL DITINJAU DARI VOLUME BETON BERTULANGNYA

Maghda Senja Gresiana

Abstrak


ABSTRAK

Gresiana, Maghda Senja. 2010. Comparative Study of Calculation Method on conventional plates and Sole Plates Joist Concrete Volume Viewed from Reinforced Concrete. Thesis, Department of Civil Engineering, State University of Malang. Advisors: (I) Drs. Prijono Bagus Susanto,S.T., M.T. 
(II) Mohammad Sulton, S.T., M.T. 

Keywords: Plate Joist, Volume Reinforced Concrete, SAP 2000. 


   Slab construction is one which is made of reinforced concrete which is a major horizontal element to distribute live load and dead load vertical to the supporting framework of the structural system. The most common plate structure used for the building is a system of plates with buffer beam through all four sides (conventional plates). Of the various types of existing plates, one of which is the model joist slab (slab ribs in one direction). The purpose of this research is to find a large volume of reinforced concrete, and compare the volume percentage of reinforced concrete on conventional plates and plates of single joist. 
This research is basically using a quantitative descriptive research. 

To generate the data needed, planning deskrptif accordance with the terms and provisions of the existing floor slab in the literature. Planning slab is analyzed by using manual / Design Direct and also uses and also uses 3D modeling frame

structural analysis program komputer/SAP2000. 

The results showed that the large volume of conventional reinforced concrete plate, viewed from the manual calculation method (direct design) and using a computer program (SAP 2000) found no difference in the volume of concrete for steel reinforcement 36.288m3 and volume of 1035.495kg. The volume of reinforced concrete on a single joist, viewed from a computer program (SAP 2000) got volume and the volume of concrete for steel reinforcement 53.262kg for 2939.067kg. For Large concrete volume percentage difference between the conventional plate with a single joist plate amounted to 31 868% and a large percentage difference in volume between the plates of conventional steel reinforcement with a single joist plates amounted to 60.8%. Can be concluded that the plate is not more efficient single joist will need reinforced concrete when

compared with conventional plates.